Core Parameter | Specification |
Capacity Range | 100 N to 50 MN across MK605-A / MK605-B / MK605-C variants |
Output Sensitivity | < 2.0 mV/V |
Nonlinearity | <= 0.05% F.S. |
Repeatability | <= 0.03% F.S. |
Recommended Excitation | 10 VDC |
Safe Overload | 120% F.S. |
Operating Temperature | -20 to +60 deg C |
Material / Protection | Alloy steel or stainless steel / IP67 |