Reference single compartment configuration
Parameter | Reference specification |
Reference working space | 500 × 500 × 500 mm(or customized) |
Observation window | 250 × 250 mm |
Exhaust connection | 100 mm diameter |
Rear relief opening | 200 × 200 mm |
Cable access port | 100 mm diameter |
Specimen: Chemistry, energy, state of charge, dimensions and expected failure event.
Interfaces: Cycler cabling, voltage and temperature sensing, exhaust and pressure relief.
Control: Remote operation, interlocks, event recording and the agreed stop logic.
Supporting equipment for selected IEC 62133-2, IEC 62619 and UN 38.3 electrical test setups; the connected test system performs the method.